- 產(chǎn)品描述
新兵服役違禁品檢測試劑條
MOP/MAMP/KET聯(lián)合檢測試劑盒(三聯(lián)卡)
檢測違禁品:Heroin, methamphetamine, methamphetamine, k powder, ice skating, ketamine, morphine, codeine, federal cough water, opium, opium, methamphetamine and other common drugs (*系統(tǒng)、*征兵用的三合一尿液檢測板)
【產(chǎn)品名稱】
通用名稱:MOP、MAMP、KET聯(lián)合檢測試劑盒(膠體金法)
英文名稱:Morphine,Methamphetamine,Ketamine Diagnostic Kit(Colloidal Gold)
[detection principle]
This product uses the antibody antigen specific binding reaction and immune membrane analysis technology, through the immune competition inhibition method to detect MOP (MOR), MAMP and KET in human urine.
The kit is placed in the MOP (MOR), MAMP and KET three test card in the detection area of the test card (line T) were coated by MOP (MOR), MAMP and KET (KET) carrier conjugates, the other end is fixed with the MOP (MOR), MAMP and KET (KET) monoclonal antibody colloidal gold disk. During the detection, if the urine contains MOP, MAMP or KET and their metabolites, antibody and MOP, MAMP or KET will support collection of objects in colloidal gold marker competition binding sites on, when they reached the concentration above the threshold concentration of product design, will be the first with colloidal gold pieces on the MOP (or MAMP or KET) monoclonal antibody reaction and antibody binding sites are occupied, thus preventing the colloidal gold on the MOP (or MAMP or KET) antibody and detection zone on the membrane of MOP (or MAMP or KET) combined detection area can not capture the colloidal gold particles and no red color shows, as a positive result. If there is no MOP in the urine (MAMP or KET) or concentration is lower than the threshold concentration, while the colloidal gold on the MOP (or MAMP or KET) antibodies and detection zone on the membrane of MOP (or MAMP or KET) carrier conjugates, the detection zone to capture the colloidal gold particles appear red ribbon, negative results.
The quality control line (C line) of the test card is coated with Goat anti mouse IgG, and the ribbon can always appear when testing, so as to indicate whether the reagent box reaction system is working normally. Quality control lines appear in the presence of prohibited substances or prohibited substances. The appearance of the quality control zone (C) ribbons showed that: 1. The amount of samples added was sufficient.
[main ingredients]
1. MOP, MAMP, KET joint detection reagent card: each reagent card consists of individual MOP test strip, MAMP test strip and KET test strip. Individually wrapped aluminum foil bags individually.
2. instruction manual (1 copies)
[storage conditions and period of validity]
The original package and 4-30 C light storage shall not be frozen and used within the validity period. Valid for 24 months.
[instrument] the result of naked eye interpretation does not require an instrument.
[own articles] 1. urine collection container: disposable clean plastic urine cup. 2. timer: used to detect timing.
[sample requirements]
Urine is collected from disposable clean urine cups, and fresh urine is recommended without any special treatment. The urine can be stored at 2-8 DEG C for 2 days, frozen for -20 months, and stored for 1-2 months. Refrigerated samples need to be restored to room temperature before testing. The frozen samples should be compley dissolved and fully mixed before they can be detected. Otherwise, the test results may be affected. Samples collected are to be tested in time.
[methods of inspection]
Please read the instruction manual carefully before testing.
The kit, urine samples and standard sample recovery at room temperature (25 degrees Celsius), in not ready before please don't rip kit kit packaging, storage in advance to the room temperature and then open the package, in order to avoid moisture absorption reagent.
Take the reagent card from the foil bag and mark the patient or sample number on the reagent card.
Pull out the reagent kit and insert the sample of the test card into the urine sample for 15 seconds. Pay attention to the plastic card and don't touch the urine sample.
Cover the kit and lay aside for 3-8 minutes. The result is invalid after 8 minutes.
[range of reference]
The minimum detectable amount of MOP was 300ng/ml, MAMP was 1000ng/ml, KET was 1000ng/ml, and the detection result was large, equal to the value of positive, less than the value is negative.
[judgment and interpretation of the results]
The MOR, M-AMP and KET labeled on the reagent card represent the MOP, MAMP and KET detection areas respectively, and the corresponding test results should be interpreted in the corresponding result observation window.
Negative: two ribbons appear in the result window. That is, the test line (T line) and quality control line (C line) position of each appear a red line. The presence of prohibited substances or prohibited substances in the sample is below the reagent detection threshold.
Positive: a red line appears on the quality control line (C line) of the result observation window. No lines appear on the test line (T line), indicating the presence of prohibited substances in the sample.
Invalid: the quality control line (C line) does not appear. In any case, the C lines shall be formed to indicate the addition and correct operation. The C line does not appear, indicating that the test result is uncertain and should be retried.
Note: a very thin ribbon appears on the test line (T line), indicating that the concentration of the banned substance in the urine is close to the detection threshold of the kit, and a more accurate and specific method is used to confirm the positive results.
更多產(chǎn)品說明可通過下方的進(jìn)行了解
添加掃一掃二維碼:
【公司名稱】 廣州健侖生物科技有限公司
【市場部】 楊永漢
【】
【騰訊 】
【公司地址】 廣州市清華科技園健新基地番禺石樓鎮(zhèn)健啟路63號二期2幢101-103室
?